Pneumatic solenoid valve doesn’t work analysis

Home news-posts Pneumatic solenoid valve doesn’t work analysis

Pneumatic solenoid valves are one of the many types of solenoid valves . 

It will inevitably fail When useing for a long time.

It is not a product quality problem, but a malfunction caused by improper use.

In this article, Jiangxi Yikai peneumatic will discuss the common troubleshooting of pneumatic solenoid valves.

 

1. The pneumatic solenoid valve is not sealed, clear or replace the oil seal first;

2. Exclude the pressure of the cylinder itself, and connect the pressure gauge to the oil outlet directly.

If the pressure is normal, it is a problem of the actuator.

3. Oil leakage or oil leakage between the fuel tank and the valve block, the ring is worn or broken, please check and replace the O-ring.

4. Oil leakage or oil leakage between the motor back cover or the motor and the valve block

5. The oil at the high pressure of the valve block is leaked, and the motor is removed.

If yes, notify the manufacturer to replace the entire power unit;

6, electrical connection error, Please check and correct wiring;

7. Start the switch to burn out, cut off the power, and replace the start switch;

8. The AC contactor burns out, the power is checked, and the AC contactor is replaced.

9, the system noise is too large

10. There is air in the system, and it works continuously several times to eliminate air;

11. The coupling is not properly installed or worn, inspected and reinstalled or replaced;

12. Do not work under extreme pressure for a long time, and stop working when the relief valve begins to overflow.

 

If have any questions about pneumatic solenoid valves/electromagnetic valves ,please feel free to contact us.Thank you.

Contact person:Blesia Zhao

Whatsapp:86-15070829677

Tel:86-791-88383977

Fax:86-791-88383677

Email:blesia@cnecan.com

www.cnecan.com

Product Categories

  • low voltage switchgear
  • electrical switchboard
  • Electrical enclosures
  • Air preparation Equipment
  • Pneumatic Valves
  • Pneumatic Cylinders
  • pneumatic fittings and tube
  • Other accessories
  • Featured Products

Product Tags

China distribution board China low voltage switchgear China Pneumatic cylinder China pneumatic FRL China pneumatic pipe and fittings China pneumatic solenoid valve China Switchboard and Enclosures compact air cylinder directional control valve electrical enclosure electrical enclosure cabinet electrical enclosures magnetic valve pneumatic fittings pneumatic silencers pneumatic valves soleniod valve stainless steel push in fittings vacuum suction cap Vacuum suction cup

Latest Post

  • How to deal with moisture in the power distribution cabinet?
    2020-11-11
  • The internal structure of the frequency converter
    2020-05-03
  • Electrical Equipment Maintenance
    2020-05-04

Email Newsletters

Jiangxi YiKai Electric produce all kinds of  Low voltage switchgear,distribution cabinet,electric panel board,MCCB Panel boards,Main switchboard,distribution panels,pneumatic solenoid valves,pneumatic cylinders, F.R.L. units,pneumatic fittings,tubing and etc.

Contact Us

JiangXi YiKai Electric Co., LTD.

No.31,JiaHai Industrial Park,High-Tech Development Zone,NanChang,JiangXi,China

Tel:86-791-88383677

Fax:86-791-88383977

Email:info@cnecan.com

www.cnecan.com

Mobile Website

Copyright © 2012-2018 JiangXi YiKai Electric Co.,Ltd. All Rights Reserved Design by cnecan.com

Inquiry Us Now !
Inquiry Us Now !